{"id":299,"date":"2019-05-09T17:23:20","date_gmt":"2019-05-09T08:23:20","guid":{"rendered":"http:\/\/ketint.dothome.co.kr\/?page_id=299"},"modified":"2019-05-09T17:24:40","modified_gmt":"2019-05-09T08:24:40","slug":"green-recloser","status":"publish","type":"page","link":"http:\/\/www.ketint.co.kr\/index.php\/green-recloser\/","title":{"rendered":"Green Recloser"},"content":{"rendered":"<p><span style=\"font-size: 18pt;\"><strong>KEY FEATURES<\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<table style=\"height: 232px; width: 911px;\" width=\"784\">\n<tbody>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><span style=\"color: #ff6600;\"><strong>Solid Insulation-environmentally friendly product<\/strong><\/span><\/td>\n<td style=\"width: 352px; height: 232px; text-align: center; vertical-align: middle; background-color: #ffffff; border-style: hidden;\" rowspan=\"8\"><img loading=\"lazy\" class=\"aligncenter wp-image-300 size-full\" src=\"http:\/\/ketint.dothome.co.kr\/wp-content\/uploads\/2019\/05\/recloser-copy-1.gif\" alt=\"\" width=\"1000\" height=\"750\" \/><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><span style=\"color: #ff6600;\"><strong>Magnetic Actuator Mechanism, Vacuum Interrupter<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><span style=\"color: #ff6600;\"><strong>Maintenance Free during its entire lifetime<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><strong><span style=\"color: #ff6600;\">Compact Design<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><strong><span style=\"color: #ff6600;\">Protection System for Fault, Frequency and Voltage<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><strong><span style=\"color: #ff6600;\">Cold load Pickup, Inrush restraints, Phase Sync. Check<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><strong><span style=\"color: #ff6600;\">58TC Curves(IEC, ANSI, Recloser-Innate, User defined Curve)<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 29px;\">\n<td style=\"width: 558px; padding-left: 30px; height: 29px; background-color: #ffffff; border-style: hidden;\"><strong><span style=\"color: #ff6600;\">Various ports for Communication and SCADA System<\/span><\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table style=\"height: 234px; margin-left: 30px;\" width=\"905\">\n<tbody style=\"padding-left: 30px;\">\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; text-align: center; background-color: #000000;\" colspan=\"2\"><span style=\"color: #ffffff;\"><strong>Maximum System Voltage<\/strong><\/span><\/td>\n<td style=\"width: 76px; text-align: center; background-color: #000000;\"><span style=\"color: #ffffff;\"><strong>kV<\/strong><\/span><\/td>\n<td style=\"width: 105px; text-align: center; background-color: #000000;\"><span style=\"color: #ffffff;\"><strong>15.5<\/strong><\/span><\/td>\n<td style=\"width: 105px; text-align: center; background-color: #000000;\"><span style=\"color: #ffffff;\"><strong>27<\/strong><\/span><\/td>\n<td style=\"width: 105px; text-align: center; background-color: #000000;\"><span style=\"color: #ffffff;\"><strong>38<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" colspan=\"2\">Rated Current<\/td>\n<td style=\"width: 76px; text-align: center;\">A<\/td>\n<td style=\"width: 105px; text-align: center;\">800<\/td>\n<td style=\"width: 105px; text-align: center;\">630<\/td>\n<td style=\"width: 105px; text-align: center;\">800<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" colspan=\"2\">Rated Voltage<\/td>\n<td style=\"width: 76px; text-align: center;\">Hz<\/td>\n<td style=\"width: 105px; text-align: center;\" colspan=\"3\">50\/60<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" colspan=\"2\">Short Time Withstand Current(3sec)<\/td>\n<td style=\"width: 76px; text-align: center;\">kA<\/td>\n<td style=\"width: 105px; text-align: center;\" colspan=\"3\">16<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" rowspan=\"2\">Impulse Basic Insulation Level<\/td>\n<td style=\"width: 217px; padding-left: 30px;\">Phase to Earth<\/td>\n<td style=\"width: 76px; text-align: center;\">kV BIL<\/td>\n<td style=\"width: 105px; text-align: center;\">50<\/td>\n<td style=\"width: 105px; text-align: center;\">60<\/td>\n<td style=\"width: 105px; text-align: center;\">70<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 217px; padding-left: 30px;\">Across Interrupter<\/td>\n<td style=\"width: 76px; text-align: center;\">kV BIL<\/td>\n<td style=\"width: 105px; text-align: center;\">50<\/td>\n<td style=\"width: 105px; text-align: center;\">60<\/td>\n<td style=\"width: 105px; text-align: center;\">70<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" colspan=\"2\">Operation Control Cabinet<\/td>\n<td style=\"width: 76px; text-align: center;\">V<\/td>\n<td style=\"width: 105px; text-align: center;\" colspan=\"3\">AC 220 or 120 and DC 24<\/td>\n<\/tr>\n<tr style=\"padding-left: 30px;\">\n<td style=\"width: 296px; padding-left: 30px;\" colspan=\"2\">Ambient Temperature<\/td>\n<td style=\"width: 76px; text-align: center;\">\u2103<\/td>\n<td style=\"width: 105px; text-align: center;\" colspan=\"3\">-40~70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>KEY FEATURES &nbsp; Solid Insulation-environmentally friendly product Magnetic Actuator Mechanism, Vacuum Interrupter Maintenance Free during its entire lifetime Compact Design Protection System for Fault, Frequency and Voltage Cold load Pickup, Inrush restraints, Phase Sync. Check 58TC Curves(IEC, ANSI, Recloser-Innate, User defined Curve) Various ports for Communication and SCADA System &nbsp; &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/pages\/299"}],"collection":[{"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/comments?post=299"}],"version-history":[{"count":8,"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/pages\/299\/revisions"}],"predecessor-version":[{"id":309,"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/pages\/299\/revisions\/309"}],"wp:attachment":[{"href":"http:\/\/www.ketint.co.kr\/index.php\/wp-json\/wp\/v2\/media?parent=299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}